Universal R-320 Manual do Operador Página 14

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 13
14
ADJUSTING PRODUCT SENSOR CONTINUED
2. After the Product Sensor is adjusted to the container, turn power to the
system on by pulling Red Emergency switch out, the Red light turns
OFF, turn Main switch ON. Turn Conveyor, Product Spacer and
Turning Unit switches to the OFF position, leaving the Applicator
switch in the ON position. Turn OFF motor switch on the label
applicator.
3. Place container under Fiber Optic Sensor. The sensor that the Fiber
Optic Cable is attached to needs to be set. It is located on the front of
the conveyor. On the sensor are a Yellow and a Blue button. Depress
either Yellow or Blue button for three seconds. Yellow button provides
Light “On” Output (Leading Edge). Blue button provides Dark “On”
Output (Trailing Edge).
NOTE: If required, use “Up” or “Down” to tweak adjustment. Turn
motor switch on the label applier back ON. (See Fig.11)
SETUP AND OPERATION CONTINUED
Yellow Button Blue Button
Fig.11